MIDAS EVO

Multi Instrument Data Aquisition Software

MIDAS Evo is the solution for those looking for a complete system for energy monitoring of the systems where they are installed Nemo and Conto models.

The system is fully configurable, in fact, you can view in real time all the measurements read by the instruments, perform historical reporting of daily, monthly and annual rates divided by preset by the user and alert email to be always at the correct operating current of own plant.

Moreover, in MIDAS Evo it is possible to discriminate the user administrator, who can access the configuration panel, and the user administrator that will only have the ability to view the project without the possibility of change.

MIDAS EVO

Licenses

MIDAS Evo is sold in four versions, if you require an upgrade to a higher version, simply buy the new license key without reinstalling the software.

CODESWMF2SWMF3SWMF5SWMF4
OPERATED TOOLS5201001024
FREE SUPPORT

APPLICATIONS

Midas Evo can be used for various applications, combined with instruments Conto's and Nemo's series.

CORPORATE LANs

Monitoring of multiple devices on the LAN to have under control the consumption of our departments.

NETWORK NOT WIRED, COMMUNICATION VIA RADIO

In some cases there isn’t possible of using an ethernet network and install a new one might be impractical, commit a lot of time and be very costly.
With Nemo 96 HD+ and his radio module (IF96018) it will be very easy and fast to reach Midas Evo also from those points “inconvenient and cramped” in terms of wiring.

DOWNLOAD THE NEMO 96HD+ / IF96018 RADIO MODULE MANUAL
Reti RS485 Protocollo Modbus RTU

CONNECTING THROUGH INTERNET

Midas Evo doesn’t necessarily have to be installed on site, you can install it where you prefer to control the instruments and remotely via the Internet, taking advantage of the ability to access measurements from anywhere in the world through the Web Server mode.

MIDAS EVO DOWNLOADS AND UPDATES

Multi Instrument Data Aquisition Software

Warning: if you have 2.07.14 version or earlier, please contact your dealer before making the update!

BACK TO ALL SOFTWARES

FAQ

Have you problems with Midas Evo? Before you contact us, try to check if one of these solutions meets its problems

1

The license key is inserted?

Always check that the license key is correctly plugged into a USB port on your PC. To confirm, you can check MidasEvo Configurator under the “License” tab:

Midas Evo - licenza

License

2

Midas Evo Configurator is properly set?

Check if the communication channel and the node address (Modbus address) of the instrument are correctly set (fig. 1).

Check also even if the instrument is actually configured the inputato node address.
Check that the communication channels are setup properly (especially the type of protocol).
If ModBus RTU, verifies all parameters with those inserted in the instrument cluster (fig. 2).

While in the case of ModBus TCP, especially make sure you have entered the IP address in its corresponding tool node address (fig. 3).

Press the button UPDATE at the end.

Midas Evo - configurator

Fig. 1

Midas Evo - modbusrtu

Fig. 2

Midas Evo - modbustcp

Fig. 3

3

The interface is on the same network?

Always check that the interface is on the same PC network.

4

There are firewall / antivirus activated?

Check that any security software does not block the communication MidasEvo outward.

1

The instruments are synchronized?

Check that you have synchronized the instrumentation

faq1

Check the synchronization all together.

  • faq-gear
  • Synchronize
faq2

Check the synchronization in the case of adding a new instrument, instrument concerned.

2

The timetable has been set / updated?

Check that the timing is correctly set (or updated in the event of the new year).

faq3
  • Consumption
  • Activate
  • Calendar Energy
3

The Windows power is turned on?

Verify that the Windows power is off (both automatic standby of a disk block).

1

Works on a Workstation?

Midas Evo can only be installed on workstations or virtual machine with USB ports support.

2

Midas Ages was initiated as an administrator?

Midas Ages needs administrator privileges to Start Properly.

1

Delete temporary files

If Midas Evo closed incorrectly, it could damage your temporary files;

Midas Evo - progetto

Navigate to the project folder:

  • Project Manager
  • IME_Application
  • Browse Project folder
  • Enter the folder Recipes and delete all files with the name CalcolaConsumiCfg.rcf in different folders. Start MidasEvo and synchronize again all the instrumentation.
icon

SUBSCRIBE TO OUR NEWSLETTER

Do you want to make sure that you are always up to date in your profession? Receive the latest news that wil help you with your work!

SUBSCRIBE